VentScope
Real-time analysis software for the Luma gas flow analyzer
VentScope turns a Windows PC into the display and control surface for the Luma gas flow analyzer. Live respiratory waveforms, a complete numeric readout, long-run trending, and direct control of the instrument’s gas settings in one clean, offline application. Connect over USB and the analyzer is detected automatically, with no network required.

Why VentScope
- Live pressure, flow, volume & O₂ waveforms, streamed at 100 Hz
- On-instrument control of gas standard & gas mixture
- Every measurement in one table, with running min / max / average
- Optional CO₂ and anaesthetic-agent analysis
- Chosen parameters trended over minutes or hours, saved to file
- 16 languages · dark & light themes · runs fully offline
See every breath in real time
- Up to three configurable plots of the live signals (pressure, flow, volume, O₂), redrawn smoothly as the analyzer streams 100 samples a second.
- Measure right on the trace: cursors for a value, a time interval, a frequency, or point-to-point. Freeze the trace and set the time window from 2 to 64 seconds.
- Key results sit beside every curve (Ppeak, PEEP, Pmean, Vte, Vti, MV, Freq, I:E), with a live sensor column for flow, pressures, temperature, humidity and oxygen.

Every number, at a glance
- The Numerics screen shows every available measurement in one table, each with its running minimum, maximum and average.
- Large, high-contrast values, meant to be read across a bench, ideal for documentation and checking against a specification.
- What the analyzer can’t measure shows as “--”, never estimated, so you always know what is real.

Watch it change over time
- Chart the parameters you choose over minutes or hours to reveal drift and stability a live trace can’t show. Trend interval from 10 ms to 10 s; up to 24 hours of history.
- Add and remove trend rows and adjust the view to focus on what matters.
- Save a full run to a file and reopen it later, giving you a permanent record of a test.

Control the instrument, not just the display
- Two toolbar dropdowns, GAS STD and GAS MIX, reach into the analyzer itself: 17 reference standards (BTPS, ATP, STPD and more) and 9 gas mixtures (Air/O₂, Heliox, N₂O/O₂ and more).
- The instrument confirms every change: the control stays amber until the analyzer reports it applied, so what you see is what the analyzer has actually accepted.
- These are the only two settings that change the instrument and, set correctly, the ones every reading depends on.

CO₂ and anaesthetic agents, built in
- With the optional gas analyzer module connected, VentScope adds CO₂ / EtCO₂ and anaesthetic-agent readouts alongside the flow measurements.
- Agent values and a dedicated alarm view keep the critical numbers in front of you.
- Choose which curves appear and colour them from a 48-colour palette; long-press any readout to change its parameter, unit and precision.

At a glance
| Platform | Windows, 64-bit |
| Software version | v1.0.1 |
| Sample rate | 100 samples/sec |
| Waveform panels | 3 configurable |
| Time window | 2 – 64 s · ~120 s waveform history |
| Trending | Interval 10 ms – 10 s · up to 24 h · save & reopen runs |
| Gas standards | 17 (BTPS, ATP, STPD and more) |
| Gas mixtures | 9 (Air/O₂, Heliox, N₂O/O₂ and more) |
| Languages | 16 · dark & light themes |
| Connection | USB (analyzer detected automatically, runs fully offline) |
Reports tab: from readings to a PDF report
Readings come straight from the LUMA, each one is judged against its acceptance limit, and the result is an A4 PDF report with device details and an overall verdict.
- ✓ Nothing typed in: every reading comes from the analyzer
- ✓ Limits from the standard, or from the ventilator's own manual
- ✓ Pass, fail or pending shown for every line
- ✓ PDF report with date, operator, serial numbers and calibration due date
Want to see VentScope running?
Talk to our team about pairing VentScope with your Luma gas flow analyzer.
Contact SalesWebstore