LUMA Gas Flow Analyzer

Accuracy in highest standards

USD 2,465

Price of the LUMA Essential Kit: the analyzer with its oxygen sensor and accessories. Price in US dollars, excluding shipping, duties and taxes.

The LUMA device is an all-in-one test solution for biomedical engineers, medical equipment companies, independent technical service providers, research labs, and manufacturers of anesthesia and ventilator systems.

LUMA Gas Flow Analyzer
LUMA gas flow analyzer, side panel with pressure and gas sensor connections
LUMA Gas Flow Analyzer
Prioritize Patient Safety. Maintain Optimal Performance of Your Critical Care Devices.

Prioritize Patient Safety. Maintain Optimal Performance of Your Critical Care Devices.

General anesthesia, facilitated by anesthesia machines, is a cornerstone of modern surgery, with procedures numbering in the hundreds of millions annually. The calibration of these devices is a matter of grave importance. Under-dosing poses the risk of unintended patient awareness during surgery, a potentially traumatic event with long-term psychological consequences. Over-dosing, on the other hand, carries the risk of life-threatening complications, including cardiac arrest. Therefore, adhering to a routine testing protocol for the ventilator and vaporizer components is fundamental to ensuring safe anesthetic delivery and protecting patient well-being.

Plug you etCO2/Gas Analyzer Sensor

Plug you etCO2/Gas Analyzer Sensor

LUMA is a compact multigas analyzer built for anesthesia and ventilator applications. It provides real-time measurement of CO₂, N₂O, and volatile anesthetic agents featuring Masimo® Technology., with all readings displayed directly on the device interface across dedicated measurement pages. LUMA is designed for fast setup and routine testing workflows, giving technicians a clear, immediate overview of gas parameters without the need for external software. All sensor alarms and status messages are shown on-screen, and measurement units can be changed instantly.

Gas Profiles and Reference Presets

Gas Profiles and Reference Presets

Flow measurements can be tailored to the test conditions by selecting the appropriate gas profile. For oxygen-enriched air, the device provides one Air/O₂ mode with automatic O₂ compensation across any set percentage so there is no separate "manual" Air/O₂ option. The seven available gas mixture profiles are: Air/O₂ (O₂-compensated across any %), Air, CO₂, N₂, He/O₂, Heliox (21% O₂), and N₂O/O₂. To support validation work, the unit also offers 17 preset reference configurations, helping you perform verification checks across a wide range of devices and operating conditions.

High-clarity display for confident, fast operation and instant access to essential parameters

High-clarity display for confident, fast operation and instant access to essential parameters

Luma is designed for immediate clarity so you can interpret key readings at a glance and stay focused on the measurement, not the menu structure. The high-resolution display renders values and curves with crisp detail, while the main screen keeps the essentials together: critical parameters, waveforms, and the controls you use most. Core configuration changes are intentionally streamlined. Gas standards, gas mixture profiles, and the most important mixture-related settings can be adjusted directly from the main screen instantly, without stepping through multiple setup pages. The result is a clean workflow with fewer steps, less distraction, and faster access to the parameters that matter.

VentScope Reports tab showing the bench set-up for a ventilator test

Fully compatible with ISO 80601 tests, from the first reading to the final report

The VentScope Reports tab is built for the tests in ISO 80601-2-12 and ISO 80601-2-13. For every test it shows the bench set-up drawing, the ventilator settings to apply and a table of the readings to capture. The readings come straight from the LUMA, so nothing is typed in by hand. Each one is judged against its acceptance limit, taken from the standard or from the ventilator's own instructions for use, and marked pass, fail or pending. When the tests are accepted, one click on Export PDF Report builds an A4 report with the date, the operator, the serial numbers of the device and of the analyzer, the calibration due date and an overall verdict, ready to file.

Learn more →

For quick details

Dimensions (W x D x H) 11.4 x 7 x 7.3 cm
Weight 0.52 kg (1.15 Ib)
Monitor size and resolution 4.3 in (256.5 mm) diagonal
800×480 pixels
with capacitive touch screen
Realtime Curves Flow, pressure, volume, temperature, oxygen, ventilation parameters
Connectivity RS-232, USB (type c), Ethernet
AC Input 100-240 VAC (50/60 Hz)
Battery operating time 5 hours
Recharge time 4 hours
Calibration Interval Once a year